Abstract

This study investigates modelling of doubly-fed induction generator (DFIG)-based wind turbines for low-frequency oscillation analysis of power systems with high penetration of distributed energy. A reduced order model of wind turbine with DFIG is proposed for small signal stability analysis in electromechanical time scale for low-frequency oscillation analysis. Furthermore, a Thevenin equivalent model of DFIG with internal voltage is also presented. Base on the derived model, the effect of phase-locked loop is emphasised, and explained by using the internal voltage derived. The model proposed is well verified by modal analysis and time-domain simulations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.