Abstract
This article presents an extensive application of component based method both at ambient and elevated temperatures. The analytical model is used to predict the connection behavior, with axial force in the connected beam being superposed. The formulas for the calculation of bending moment resistance and rotation stiffness are derived in the article. At the same time, two kinds of loading paths, proportional loading and non-proportional loading, are also thoroughly investigated. A total of 12 tests, in which the connection is subjected to proportional loading path, are utilized to validate the analytical model. At the same time, a 3D Finite Element Model using the ABAQUS is also presented to verify the analytical model. As to the connection under non-proportional loading path, 6 transient fire tests are chosen to verify the proposed model. Compared to the experimental results, the accuracy of the moment-rotation curves obtained from the analytical model are acceptable. Hence, the presented analytical model can be used to predict connection behavior under fire conditions, taking the influence of axial force into account.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.