Fully explicit finite-difference simulation in oblate spheroidal coordinates is employed as a means of modelling concentrations near, and flux density at, an inlaid disk electrode under total diffusion control. The simulated current-versus-time relationship is found to concur excellently with those of dissimilar studies.