Abstract

A modular modelling approach was adopted to build a dynamic simulation model of the moisture separation reheater on a high-precision APROS real-time platform to investigate the dynamic operating characteristics of the moisture separation reheater. The model was subjected to steady-state and step dynamic tests at different loads. The results show that the established model can correctly reflect the steam flow and heat transfer properties and can meet the requirements of the simulation. Using the one-dimensional distribution of the model, the effect of a small breakage failure in the heat exchanger bundle was further investigated. The results showed that the heat transfer tube bundle had leaks, reducing the heat transfer capacity and affecting the quality of the steam used to work in the low-pressure turbine. Simultaneously, the effect on steam outlet parameters increased with the degree of leakage in the heat exchanger.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call