Abstract

The stray currents are the fraction of traction return current returning by earth in at grade configurations, or by metallic structures (reinforcement bars) in case of viaducts and tunnels. These currents expose steel reinforcement bars to corrosion. The obvious alternative to minimize the risk of corrosion is to minimize the stray current, using insulation sleeper insulating pads and insulated bolts in fastener blocks. However, due to mechanic wearing by train operation, aging, or accumulation of waste, the level of insulation between rail and structures decreases with time, which increases the stray currents. A common palliative method for this is to install a Stray Current Collector (SCC), a conductive grid or mat, embedded in the concrete structure below the rails. The SCC can be connected to earth and to return circuit in different ways. The objectives of the paper are to get a model of leakage resistances including the SCC system, to determine the effectiveness of SCC and the best connection scheme.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.