Abstract

The one-dimensional imager of neutrons (ODIN) at the Sandia Z facility consists of a 10-cm block of tungsten with rolled edges, creating a slit imager with slit widths of either 250, 500, or 750 μm. Designed with a 1-m neutron imaging line of sight, we achieve about 4:1 magnification and 500-μm axial spatial resolution. The baseline inertial confinement fusion concept at Sandia is magnetized liner inertial fusion, which nominally creates a 1-cm line source of neutrons. ODIN was designed to determine the size, shape, and location of the neutron producing region, furthering the understanding of compression quality along the cylindrical axis of magnetized liner implosions. Challenges include discriminating neutrons from hard x-rays and gammas with adequate signal-to-noise in the 2 × 1012 deuterium-deuterium (DD) neutron yield range, as well as understanding the point spread function of the imager to various imaging detectors (namely, CR-39). Modeling efforts were conducted with MCNP6.1 to determine neutron response functions for varying configurations in a clean DD neutron environment (without x-rays or gammas). Configuration alterations that will be shown include rolled-edge slit orientation and slit width, affecting the resolution and response function. Finally, the experiment to determine CR-39 neutron sensitivity, with and without a high density polyethylene (n, p) converter, an edge spread function, and resolution will be discussed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call