Abstract

This research investigates the effect of downstream drain’s geometry on seepage through homogeneous earth dams founded on an impervious foundation. A permeability tank experimental model and SEEP2D numerical model are used in the study. The dam’s failure in the case of no drain is experimentally observed to point out the drain’s importance. The effect of the drain’s geometry on seepage characteristics is evaluated by considering different scenarios for its height, length, and angle. Three cases for reservoir filling are studied. Sensitivity analysis is performed to evaluate the drain’s most effective geometrical parameter. The results show that the most effective geometrical parameter of the downstream drain is its length, while its height and angle have no effect. Increasing the drain’s length increases the seepage discharge and the distance between the phreatic line and downstream face and reduces the pore water pressure leading to more safety. Design charts and equations are provided.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.