Abstract
AbstractThe dispersed phase holdup and drop size in solvent extraction columns vary along the column height and this affects the mass transfer coefficient and interfacial area. In this article, mass transfer study was performed experimentally using a 25 mm diameter agitated pulsed column. The axial distribution of mass transfer coefficient was determined by coupling population balance equation and axial dispersion model by taking the longitudinal variation in hydrodynamic performance into consideration. Feasibility of different mass transfer models in predicting concentration profiles was evaluated and a novel correlation based on effective diffusivity was developed. The results showed that both overall and volumetric mass transfer coefficients have significant change along the column height and greatly depends on the agitation speed and pulsation intensity. Increasing dispersed phase velocity also augments the overall mass transfer coefficient. The maximum number of transfer unit was measured to be 10 m−1 at agitation speed of 1000 rpm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.