Abstract

Transit time clamp-on ultrasonic flowmeters (UFMs) are widely used in industry due to their ease of installation. However, these ultrasonic clamp-on flowmeters are also known to be less accurate than ultrasonic inline flowmeters because of the uncertainties induced by the installation process. Amongst the installation-related parameters that influence the measurement uncertainties, internal pipe wall roughness is one of the most significant but uncontrollable parameters. The effect of roughness on accuracy can be reduced by operating the flowmeter at a longer wavelength. This article investigates the effect of roughness on a clamp-on UFM using low-frequency (200 kHz) leaky Lamb waves. This results in operation at roughly five times lower frequency compared with conventional clamp-on UFMs. The ultrasonic signals of this leaky Lamb wave UFM were simulated using the 2-D finite-element (FE) analysis. Using the simulated signals, the roughness effects on the uncertainties were quantified. The simulation results show that the uncertainty related to pipe wall roughness of leaky Lamb wave UFMs is approximately half that of conventional UFMs for corroded pipe walls with rms value larger than 0.1 mm (0.2, 0.35, and 0.5 mm). Demonstration experiments were also carried out to detect leaky Lamb wave using an electromagnetic acoustic transducer (EMAT). The experiment shows that the simulation correctly captures all the physics of the wave propagation and that we, therefore, can trust the simulation results with incorporated roughness.

Highlights

  • T RANSIT time clamp-on ultrasonic flowmeters (UFMs) are widely used in many industries because they are noninvasive and easier to install compared with inline UFMs [1]

  • The uncertainties due to other sources are assumed to be zero, and we only focus on the nonflow profile-related scattering of ultrasound at the internal pipe wall roughness

  • It can be seen that using leaky Lamb wave UFMs, the roughness-related uncertainties are reduced by approximately 50% compared with conventional UFMs for rms values larger than 0.1 mm (0.2, 0.35, and 0.5 mm)

Read more

Summary

Introduction

T RANSIT time clamp-on ultrasonic flowmeters (UFMs) are widely used in many industries because they are noninvasive and easier to install compared with inline UFMs [1]. The installation of these clamp-on flowmeters only requires transducers to be mounted onto the outside of the pipe wall to transmit and receive an ultrasound, whereas inline flowmeters require cutting of the pipe and insertion of a spool piece. Manuscript received September 20, 2019; revised December 17, 2019; accepted February 9, 2020. Date of publication February 20, 2020; date of current version August 11, 2020. The Associate Editor coordinating the review process was Chao Tan. (Corresponding author: Xiaotang Gu.)

Objectives
Methods
Findings
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.