Abstract

Geometrically similar ramjet-type combustion chambers of 1.61, 4.026, and 6.065-inch diameter and lengths of 5.25D and 4.25D were operated at Reynolds numbers ranging from 24,000 to 230,000 and ambient pressure levels from 0.2 to 1.5 atmospheres, with propane fuel. Flameholders were annular V-gutters having a leading-edge included angle of 30° and producing 44% blockage of the combustor cross section. Excepting the wall thickness of some burners, all dimensions of burners, flameholders, upstream piping and mixing sections were scaled in proportion to burner inside diameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.