Abstract

The refractive index of bulk poly(methyl methacrylate) samples is modified by X-ray exposure. The intensity of the radiation is distributed over an energy range of 1 to 20 keV with a maximum at 3 keV. For an absorbed dose of about 1 kJ cm(-3), an increase of the refractive index of up to 3x10(-4) is observed. However, for much lower doses of about 10 J cm(-3) a decrease of 4x10(-4) appears. These refractive index changes, as well as the simultaneously arising radiation-induced thickness changes, are detected interferometrically. Based on these observations, on dose calculations, and on literature data, a model is proposed which describes quantitatively the observed refractive index changes. The refractive index increase is caused by a radiation-induced chemical alteration of the polymer composition, while the refractive index decrease is correlated with a decrease of mass density.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.