Abstract

This paper addresses the occurrence of stator faults in six-phase induction machines, with a symmetrical winding, operating under both balanced and unbalanced supply voltage conditions. A dynamic model of the motor was developed in Matlab/Simulink environment, taking into consideration the occurrence of inter-turn short circuit faults. To validate the proposed approach, simulation results, covering the full range of operation and different fault severity levels, are compared with the motor experimental performance. The voltages and currents obtained from the simulation present a good agreement with the corresponding experimental results, demonstrating the accuracy of the proposed model

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.