The strip temperature is affected by many factors in rapid cooling section (RCS) of the vertical continuous annealing furnace (VCAF). They can be divided into four types: the physical properties of cooling gas, the geometry characteristics of configuration of cooling equipment, the heat transfer between the strip and the cooling gas, and the conductivity of the strip. It aims to model the strip temperature in the cooling section based on the fundamental heat transfer theory and the four aspects factors. The model for transient Nusselt number is obtained by considering Reynolds number, Prandtl number and geometry characteristics of RCS. Then cooling model of the strip transient temperature is built by Nusselt number, heat transfer coefficient and heat conductivity of the strip. The results are compared with the data from production line. The comparisons indicate that the model can well predict cooling temperature of the strip. It is hoped that the proposed model can be used for design and control of the vertical continuous annealing furnace.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.