Abstract

The energy dissipation characteristics of steel tube clusters are investigated with a view toward using such a system as a stationary energy absorbing device. Experiments performed on small scale models made up by connecting mild steel rings cut from tube stock are described. Six different configurations were chosen for testing to establish their stability and load-carrying capabilities, and all systems were tested both quasi-statically and dynamically. The energy absorption properties of all six systems are shown to be remarkably insensitive to the line of action of the loading. For a given kinetic energy, an individual system collapsed by essentially the same amount regardless of whether the impact angle was 0° or 15° with respect to the line of symmetry of the device. A design example is presented in the paper to illustrate how the results of the model tests can be applied to design a full scale impact attenuation device.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.