Abstract

Hexavalent plutonium (Pu(VI)) is an important solute in the PUREX (plutonium uranium extraction) process. In 30 % TBP based PUREX solvent extraction system, distribution coefficient of Pu(VI) is much lower than that of Pu(IV). This lower distribution coefficient of Pu(VI) may cause unexpected Pu loss during primary HA extraction in low acid flowsheets. An empirical model for Pu(VI) distribution coefficients in 30 % TBP and its temperature dependency has been reported in this paper. Comparison with literature data revealed a reasonably good agreement between the reported experimental and model predicted values.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call