Abstract

With the advent of pulse energization in electrostatic precipitators, the need for developing a model to simulate the physical processes in the prebreakdown region, at which the precipitator normally operates, is also increasing. The development of such a model helps in predicting the VI characteristics of a precipitator, which will be important to diagnose the electrical problems associated with the precipitator during its operation. The paper reports the details of a proposed model to predict the VI characteristics of a wire-plate precipitator operating under the influeuce of repetitive pulses superposed on a dc bias. The model begins with the calculation of space charge density near the HV electrode during the pulse-on period and then proceeds with the drift of space charges in the pulse-off period aided by the dc bias. The pulse duration was /spl sim/250 ns. The pulse repetition rate was 50 Hz. The predicted results were validated against the experimental results conducted on a laboratory model of a wire-plate precipitator. The studies were conducted for dust free conditions. >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.