Abstract
Sample calculations were performed with a three-dimensional (3-D) finite-element model analysis that describe the response of an eddy current (EC) probe to steam generator (SG) tubing artifacts. Such calculations could be very helpful in understanding and interpreting of EC probe response to complex tube/defect geometries associated with the inservice inspection (ISI) of steam generator (SG) tubing. The governing field equations are in terms of coupled magnetic vector and electric scalar potentials in conducting media and of total or reduced scalar potentials in nonconducting regions. To establish the validity of the model, comparisons of the theoretical and experimental responses of an absolute bobbin probe are given for two types of calibration standard defects. Preliminary results are also presented from a recent theoretical study of the effect of ligament size in axial cracks on EC indications with conventional ISI bobbin probes.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.