The present work introduces a way of predicting the local heat transfer coefficient in the combustion chamber of a circulating fluidized bed combustor (CFBC) by the fuzzy logic (FL) approach.Fuzzy logic techniques have been successfully applied to calculate the overall heat transfer coefficient for membrane-walls in the combustion chamber of the 670 t/h CFB boiler. The previously obtained heat transfer coefficients values have been used to build up a simple FL model. It has been shown, that the presented fuzzy logic approach give quick and accurate results as an answer to the input data set. The local heat transfer coefficients evaluated using the developed model have been in a good agreement with the desired data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.