Abstract

Soft magnetic composites (SMCs) are composed of ferromagnetic particles surrounded by electrical insulation. To establish a homogenization technique for the magnetic field analysis of an electrical machine with an SMC core, we have already proposed a method to evaluate the effective permeability and iron loss of the SMC core using a cell model of one particle taking into account the nonlinear magnetic characteristics and eddy currents. However, the measured eddy current loss cannot be represented by using the proposed method. In this article, a 3-D eddy current analysis method modeling the anomalous eddy current loss due to the movement of domain walls in the cell model is developed based on the Pry and Bean magnetic domain model. The effect of the non-uniformity of the domain structure on the anomalous eddy current loss is investigated. It is shown that the measured eddy current loss can be almost represented by adding the anomalous eddy current loss to the classical one.