Abstract

A new method for modeling stator winding fault with one shorted coil in a switched reluctance motor (SRM) is presented in this paper. The method is based on artificial neural network (ANN), incorporated with a simple analytical model in electromagnetic analysis to estimate the flux-linkage characteristics of SRM under the stator winding fault. The magnetic equivalent circuit method with ANN is applied to calculate the nonlinear flux-linkage characteristics under stator winding fault condition. A stator winding fault 12/8 SRM prototype system is developed to verify the effectiveness of the proposed method. The results for a stator winding fault with one shorted coil are obtained from the proposed method and from the experimental work on a developed prototype. It is shown that the simulation results are close to the test results.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call