Abstract

In order to gain experience in explosive pulsed power and to provide experimental data as the basis for computer modeling, a small high-explosive-driven helical magnetic flux-compression generator (FCG) was designed at the Swedish Defence Research Agency. The generator, of which three have been built, has an overall length of 300 mm and a diameter of 70 mm. It could serve as the energy source in a pulse-forming network to generate high-power pulses for various loads. This paper presents a simulation model of this helical FCG. The model, which was implemented in Matlab-Simulink, uses analytical expressions for the generator inductance. The model of resistive losses takes into account the heating of the conductors and the diffusion of the magnetic field into the conductors. The simulation results are compared with experimental data from two experiments with identical generators but with different seed currents, influencing the resistive losses. The model is used to analyze the performance of the generator.