Abstract
A new type of the sensitive specimen named ‘ G c -sensing element’ that can be fabricated, using the plain and general micro-fabrication process, is proposed and modeled to measure the interfacial toughness G c of metal thin films on substrates. For the whole modeling process of the G c -sensing element, the finite element method and the concepts of the linear elastic fracture mechanics are applied. Moreover, the verification for energy-release rates calculated from the linear elastic fracture analysis is carried out, using the elastic–plastic fracture analysis. The results of this research show that the G c -sensing element provides a simple and convenient method for measuring the precise interfacial toughness of metal thin films on substrates.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.