Abstract

Secondhand exposure to environmental tobacco smoke (ETS) in multifamily housing remains a health concern despite strong recommendations to implement non-smoking policies. Multiple studies have documented exposure to ETS in non-smoking units located in buildings with smoking units. However, characterizing the magnitude of ETS infiltration or measuring the impact of building interventions or resident behavior on ETS is challenging due to the complexities of multifamily buildings, which include variable resident behaviors and complex airflows between numerous shared compartments (e.g., adjacent apartments, common hallways, elevators, heating, ventilating and air conditioning (HVAC) systems, stack effect). In this study, building simulation models were used to characterize changes in ETS infiltration in a low income, multifamily apartment building in Boston which underwent extensive building renovations targeting energy savings. Results suggest that exterior wall air sealing can lead to increases in ETS infiltration across apartments, while compartmentalization can reduce infiltration. The magnitude and direction of ETS infiltration depends on apartment characteristics, including construction (i.e., level and number of exterior walls), resident behavior (e.g., window opening, operation of localized exhaust fans), and seasonality. Although overall ETS concentrations and infiltration were reduced post energy-related building retrofits, these trends were not generalizable to all building units. Whole building smoke-free policies are the best approach to eliminate exposure to ETS in multifamily housing.

Highlights

  • IntroductionDespite prevention and cessation campaigns, exposure to environmental tobacco smoke (ETS)

  • Despite prevention and cessation campaigns, exposure to environmental tobacco smoke (ETS)remains a significant health concern, in multifamily housing

  • Seasons, window opening, and exhaust fan scenarios, 24-h average predicted concentrations of ETS PM2.5 generated from in-unit smokers present in all units ranged between 16 and 152 μg/m3 pre retrofit, and between 16 and 185 μg/m3 post retrofit

Read more

Summary

Introduction

Despite prevention and cessation campaigns, exposure to environmental tobacco smoke (ETS). Remains a significant health concern, in multifamily housing. ETS refers to a mixture of over 7000 organic and inorganic chemicals that are released into ambient air as gas or particles when exhaled from mainstream smoke, or produced as sidestream smoke from smoldering tobacco product. This mixture contributes to fine particulate matter 2.5 μm in diameter) in the indoor environment [1,2,3]. Res. Public Health 2016, 13, 327; doi:10.3390/ijerph13030327 www.mdpi.com/journal/ijerph

Objectives
Methods
Results
Discussion
Conclusion