Abstract
A method to model compartmentalized groundwater systems is described. The method is based on the evaluation of a data set of pore pressure measurements from vibrating wire piezometers and open standpipe piezometers. Measurements were obtained from an area of approximately 5 mi 2 (13 km 2 ). The method was developed in light of the prohibitive cost of installing instruments in each of the approximately 300 groundwater compartments in the study area. Modeling pore pressure across the groundwater compartments is accomplished through the use of reliability methods that account for the range of pore pressures by elevation and material type. The method is most applicable for modeling extensive, highly compartmentalized groundwater systems in heterogeneous material types. As the method relies solely on pore pressure measurements and does not take into account pumping rates, boundary conditions, aquifer characteristics, or other aspects for modeling a transient system, only limited forward projection of the pore pressure distribution is possible.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.