Abstract
A large-signal average model for the controlled on-time boost power factor correction (PFC) circuit is developed and subsequently linearized resulting in a small-signal model for the PFC circuit. AC analyses are performed using the small-signal model, revealing new results on small-signal dynamics of the PFC circuit. The analysis results and model predictions are confirmed with experimental measurements on a 200 W prototype PFC circuit.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.