This article establishes an analytical model for the device drain–source overvoltage related to the two loops in three-level active neutral point clamped (3L-ANPC) converters. Taking into account the nonlinear device output capacitance, two common modulation methods are investigated in detail. The results show that the line switching frequency device usually has higher overvoltage, and the switching speed of the high switching frequency device is not strongly influenced by the multiple loops. By keeping the nonactive clamping switch off , the effect of the nonlinear device output capacitance can be significantly mitigated, which helps reduce the overvoltage. Moreover, the loop inductance can be reduced with vertical loop layout and magnetic cancellation in the printed circuit board and busbar design. A 500-kVA 3L-ANPC converter using silicon carbide mosfet s was built and tested. The experimental results validate the overvoltage model of the two modulation methods as well as the busbar design. With the nonactive clamping switch off , the overvoltage of both the high and line switching frequency devices is significantly reduced, which helps achieve higher switching speed.