Abstract
In Part I: Modeling Foundations [1], a comprehensive model of an ultrasonic nondestructive evaluation (NDE) flaw measurement system was developed. Here, it will be shown that this comprehensive model can be used to completely characterize commercial measurement systems where all the elements of the system can be either modeled explicitly or measured, using purely electrical measurements. When combined, these models and measurements are shown to be able to predict accurately the measured signals in an ultrasonic test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.