The better improvement on the system performance of R-410A inverter air conditioner was performed. The proper operating strategies of whole system with evaporatively cooling unit were investigated experimentally and numerically. The adapting system was tested by varying of frequency, water flow rate and spraying temperature. Fortunately, the combined system obtained an extended frequency range of 30–90 Hz properly. A longer capillary tube length of 887 mm with a lower optimal charge of 1.1 kg was chosen for the water temperature closed to inlet wet-bulb temperature. The water injection rate of 200 l/h obtains the best COP at a low frequency range while the flow rate of 100 l/h being at a high frequency range. Finally, the integrated model and the leakage inventory model were developed to predict the performance and the optimal charge, respectively. It can be concluded that the proposed models give a satisfactory agreement with test data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.