Abstract

The characteristics of the prevention of electrolytic corrosion during micro electrical discharge machining (EDM) using deionized water and high frequency bipolar pulse were investigated. Electrolytic corrosion during micro EDM using deionized water was analyzed using an equivalent electrical circuit based on the electrical double layer theory. Based on the analysis and experimental verification, a narrow positive pulse duration should be provided to the workpiece to prevent corrosion. A negative voltage with zero average applied voltage (Vavg, app) is also essential for this purpose. If Vavg, app is positive or negative, electrolytic corrosion occurs on the workpiece or tool, respectively. Micro holes and 3D structures without corrosion were successfully fabricated using a high frequency bipolar pulse with a pulse duration of 0.2 μs and a period of 1 μs, as well as Vavg, app = 0 V.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.