Abstract

Unique pitfalls in parallel three-level T-type inverters (3LT 2 Is) are potential zero-sequence circulating currents (ZSCCs) which are more complex than parallel two-level inverters and can cause current discrepancy, current waveform distortion, power losses, etc. In this paper, the ZSCC paths in the parallel 3LT 2 Is are first presented, and an equivalent model of the ZSCCs is developed. It is seen from this model that the ZSCCs consist of conduction, switching, and hybrid components. Based on the aforementioned analysis, an original sharing neutral bus structure is proposed to eliminate the conduction ZSCCs. With regard to the switching ZSCCs composed of high-frequency and low-frequency harmonics, modified LCL filters are proposed to eliminate the former, and zero-sequence control loops are put forward to suppress the latter. Furthermore, the proposed schemes are also proven to be effective to elimination of the hybrid ZSCCs. Experimental results validate the developed models and the proposed ZSCC elimination schemes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.