Abstract

Electrical Capacitance Tomography (ECT) is an imaging technique which generates a cross-sectional image representing the internal permittivity distribution based on external capacitance measurements. It possesses the advantages of being non-radioactive, non-intrusive, non-invasive, high imaging speed and low cost over the conventional imaging techniques. Inter-electrode capacitance measurements are done by exciting electrodes placed around the non-conductive dielectric medium cylinder inside which, the material to be imaged is placed. This paper emphasizes on modelling and calibrating an electrical capacitance tomography sensor using ANSYS APDL with medium as air, water and extending the procedure for normal bone and cracked bone. ECT sensor is modelled by mounting 12 electrodes symmetrically outside the cylinder. The cylinder is made up of Polyvinyl Chloride (PVC) which is non-conductive dielectric medium while the electrodes are made up of Copper (Cu) which is conductive. The electrodes are excited in pairs and the potential distribution which is based on permittivity of the medium is analysed using ANSYS and the capacitance between the electrodes were calculated. The entire electrode modelling, calibration and capacitance measurement for the simulated bone model with and without crack is presented in this paper.

Highlights

  • Electrical Capacitance Tomography (ECT) is an imaging technique which generates a cross-sectional image representing the internal permittivity distribution based on external capacitance measurements

  • The electrodes are excited in pairs and the potential distribution which is based on permittivity of the medium is analysed using ANSYS and the capacitance between the electrodes were calculated

  • The term tomography refers to the process of exploring the internal characteristics of a specified region through measurements related to the internal characteristics of the specified area

Read more

Summary

Introduction

Electrical Capacitance Tomography (ECT) is an imaging technique which generates a cross-sectional image representing the internal permittivity distribution based on external capacitance measurements. Interelectrode capacitance measurements are done by exciting electrodes placed around the nonconductive dielectric medium cylinder inside which, the material to be imaged is placed. This paper emphasizes on modelling and calibrating an electrical capacitance tomography sensor using ANSYS APDL with medium as air, water and extending the procedure for normal bone and cracked bone.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.