Abstract

Designing proper solid oxide fuel cell (SOFC) system configurations is essential for their high efficiency. The present study analyzes the performance improvement of the SOFC system with anode off-gas recirculation (AOGR). Two AOGR configurations are suggested. Depending on the heat flows of off gases, the configurations are called AOGR #1 and #2, respectively. Additionally, a reference system is examined for comparison. This study aims to numerically evaluate the characteristics and performance of each system under various operating conditions such as fuel and air utilization factors. The operating current density and steam to carbon ratio are fixed at 0.3 A/cm2 and 2.5, respectively. The results indicate that the system performance shows a large difference depending on the system configurations. The SOFC system with AOGR has better performance than the reference system under the operating conditions considered in this paper. However, it is also revealed that depending on the system configuration and operating conditions, AOGR can be effective or ineffective for system performance. Therefore, a deliberate operating strategy for AOGR systems needs to be developed based on the load conditions.