Abstract

Hydrogen leaks are potentially dangerous faults in fuel cell systems that are fed with hydrogen-rich gas mixtures. This brief presents an approach to hydrogen leak detection and, thus, complements direct detection using hydrogen sensors. It relies on simple mass balance equations of an anode filling volume after taking into account the natural leak of the stack. A hydrogen mass flow, anode pressure, and relative humidity sensor are employed. Hydrogen leak detection without the use of relative humidity sensors is considered by employing adaptive alarm thresholds to eliminate false alarms. The validity of the method is also discussed in terms of common hydrogen supply system configurations. The detection method is validated using a 1.25-kW polymer electrolyte membrane fuel cell stack in a laboratory facility where leaks could be introduced in a controlled manner.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.