Abstract
In the present paper, the internal model control (IMC) method is introduced and applied to AC machine current control. A permanent magnet synchronous machine is used as an example. It is shown that the IMC design is straightforward and the resulting controller is simple to implement. The controller parameters are expressed in the machine parameters and the desired closed-loop rise time. The extra cost of implementation compared to PI control is negligible. It is further shown that IMC is able to outperform PI control with as well as without decoupling with respect to dq variable interaction in the presence of parameter deviations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.