Abstract

A series of tests was conducted to characterize the indoor carbon monoxide (CO) concentrations resulting from portable electric generators operating in the attached garage of a test house under various use and environmental conditions. An extensive model validation effort using the multizone airflow and indoor air quality (IAQ) model CONTAM was carried out using the data from seven tests with a generator operating in the attached garage to compare predicted CO concentrations with measured values. The agreement between the measurements and predictions of the O2 concentrations in the garage and the average CO concentration for the house zones was excellent for the data set as a whole. The agreement was somewhat worse for the garage CO concentrations. Overall, the house zone average and garage CO concentration predictions and measurements were within about 20% and 30%, respectively, when averaged over all cases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.