Abstract

AbstractModel testing for soft soil foundations with and without a prefabricated vertical drain (PVD) was performed to assess the consolidation and long-term performance of PVDs. Surface settlements and excess pore-water pressures at different depths were monitored throughout the applied multistage loading. Classical methods with improved solutions that considered variations in the discharge capacity and non-Darcian flow were applied via a back-analysis of the consolidation results. Parameters related to the smear effect and well resistance were discussed in these solutions. It was found that the foundation improved with PVD had an approximately 20% increase in the total degree of consolidation compared with untreated soft soil foundations; the well resistance of the PVD system not only existed but it also changed over time; the average discharge capacity in the model test under multistage loading condition was far less than the reported value; and the advanced solutions, especially the solution that cons...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.