Abstract

Experimental study of hydraulic physical model investigates the flow characteristics in the pump sump. The model features four pumps (7.91 L/s for pump 1 and 2, and 4.74 L/s for pump 3 and 4) with a total of 9 cases of study. Different values of water depth (180mm, 200mm, and 300mm) and pump flow rate (15L/s, 20L/s, and 25L/s) were conducted. Velocity measurements at the dividing cross section were obtained by an Acoustic Doppler Velocimeter (ADV), pump flow rate by flow meter (Dyna Handheld Transit Time Ultrasonic Flow Meters) and swirl angle in the suction intakes were measured by a vortimeter/rotometer. No vortices were occurred near the suction intake at the high and medium water level conditions. In the low water level condition with high flow rate (25L/s), vortex Type 4 or 5 were observed near the suction intake and this condition is unacceptable. Since this condition indicate the presence of vortices more than Types 2 and an uneven flow through the suction intake, this can be categorized as the worst case and not recommended for pump sump operation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.