Abstract

A model predictive control method to reduce the common-mode voltage (MPC-RCMV) with constant switching frequency for PMSM drives is proposed in this paper. Four nonzero VVs are adopted in future control period and the switching sequence is designed to ensure the switching frequency is fixed and equal to the control frequency. By substituting the finite-control nonzero voltage vectors in the current predictive model, a current predictive error space vector diagram is obtained to determine the adopted four VVs. The duty ratio calculating method for the selected four VVs is studied. Compared with the conventional MPC-RCMV method, the current and torque ripples are greatly reduced and the switching frequency is fixed. The simulation and experiment results validate the effectiveness of the proposed method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.