Abstract
During 1977 and 1978, a Fission Neutron Water Factor Model was designed and constructed by Bendix Field Engineering Corporation (BFEC) for the United States Department of Energy (DOE) at the Grand Junction facility. This model features seven water-filled boreholes with different diameters. All of these boreholes penetrate, in order from the top of the model, a 5-foot-thick (1.52 m), uniform, concrete upper ''barren zone''; a 6-foot-thick (1.83 m), uniform, uranium-enriched, concrete ''ore zone''; and a 4-foot-thick (1.22 m), uniform, concrete lower ''barren zone''. The response of a fission neutron logging tool in a water-filled borehole is affected by variations in the borehole diameter. This diameter-dependent effect can be deduced from logs run in several different boreholes of the Fission Neutron Water Factor Model. This report describes the construction of the Fission Neutron Water Factor Model and also presents values for model parameters which are of interest in fission-neutron logging.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.