Abstract

This paper presents an electric equivalent model of the Induction Electrodeless Fluorescent Lamps (IEFL). The model is based on resistances and reactances and takes into account the real and reactive lamp power. One of the most important features of the proposed methodology is the concern regarding core losses and lamp reactive characteristics. In order to obtain and validate the IEFL model, a series-parallel resonant half-bridge inverter is used as the ballast power stage. Lamp discharge and coils are modeled as resistances and reactances depending on the lamp power. Simulations employing the proposed model are presented in this paper and they are in agreement with experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.