Abstract

BackgroundCurrently, radiation therapy treatment planning system intends biological optimization that relies heavily upon plan metrics from tumor control probability (TCP) and normal tissue complication probability (NTCP) modeling. Implementation and expansion of TCP and NTCP models with alternative data is an important step towards reliable radiobiological treatment planning. In this retrospective single institution study, the treatment charts of 139 lung cancer patients treated with chemo-radiotherapy were reviewed and correlated dosimetric predictors with the incidence of esophagitis and established NTCP model of esophagitis grade 1 and 2 for lung cancer patients.MethodsEsophagus is an organ at risk (OAR) in lung cancer radiotherapy (RT). Esophagitis is a common toxicity induced by RT. In this study, dose volume parameters Vx (Vx: percentage esophageal volume receiving ≥ x Gy) and mean esophagus dose (MED) as quantitative dose-volume metrics, the esophagitis grade 1 and 2 as endpoints, were reviewed and derived from the treatment planning system and the electronic medical record system. Statistical analysis of binary logistic regression and probit were performed to have correlated the probability of grade 1 and 2 esophagitis to MED and Vx. IBM SPSS software version 24 at 5% significant level (α = 0.05) was used in the statistical analysis.ResultsThe probabilities of incidence of grade 1 and 2 esophagitis proportionally increased with increasing the values of Vx and MED. V20, V30, V40, V50 and MED are statistically significant good dosimetric predictors of esophagitis grade 1. 50% incidence probability (TD50) of MED for grade 1 and 2 esophagitis were determined. Lyman Kutcher Burman model parameters, such as, n, m and TD50, were fitted and compared with other published findings. Furthermore, the sigmoid shaped dose responding curve between probability of esophagitis grade 1 and MED were generated respecting to races, gender, age and smoking status.ConclusionsV20, V30, V40 and V50 were added onto Quantitative Analysis of Normal Tissue Effects in the clinic, or QUANTEC group’s dose constrains of V35, V50, V70 and MED. Our findings may be useful as both validation of 3-Dimensional planning era models and also additional clinical guidelines in treatment planning and plan evaluation using radiobiology optimization.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call