Abstract
The buildup of an insoluble corrosion product in the annulus between the tube-to-tube-support-plate in some operating nuclear steam generators has resulted in a deformation or “denting” of the heat transfer tubes. A series of tests were initiated in single-tube model boilers to investigate the denting corrosion process and to determine additives and practices that would arrest this corrosion process. Test results show that properly administered additions of boric acid, sodium phosphate, or calcium hydroxide are capable of stopping the corrosion process leading to denting. Furthermore, it was determined that additions of either boric acid or lithium borate are effective in dent prevention, and this was demonstrated by adding contaminants and inhibitor simultaneously to a nondented test specimen.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.