Abstract
In this study, modal and structural identification of a historic masonry bell tower in Čuntići, Croatia, damaged during the recent Petrinja earthquake, was performed. The results of the ambient vibration tests (AVT) and operational modal analysis (OMA) were used to update the finite element numerical model of the bell tower. Three modes were experimentally determined: the first two were bending modes (f1 = 4.395 Hz and f2 = 4.639 Hz), and the third was a torsional mode (f3 = 10.303 Hz). The experimentally determined and the originally calculated (preliminary NM) modal shapes agreed well, but in terms of modal frequencies, the correlation was poor. After model updating, some structural parameters were identified, and a reliable finite element numerical model was established. The proposed method can provide a reliable evaluation of the structural parameters of historic masonry buildings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.