The article describes the pulse power system for electric-discharge blasting of rocks and concrete, the main equipment of which is a high current pulse generator with operating voltage up to 15 kV. The test of short-circuit experiment was produced, the main parameters of the discharge circuit L = 1.01 μH, R = 9 mΩ were calculated. Based on the results of the experiments the impedance Z = 42.5 mΩ of discharge circuit was defined. The pulse power system with mentioned parameters has maximum power condition deviation of about 8.6 %.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.