A necessary condition for a large-scale steam explosion in a core meltdown accident in the light water reactor is the formation of a coarsely predispersed mixture of molten fuel and water. Chapman-Jouguet diagrams for tin-water mixtures indicate that thermal detonations at supercritical pressures are possible only with relatively low initial void fractions (<0.15). The calculations present deal with a one-dimensional array of fuel particles falling steadily from the lower tie plate into the lower plenum pool. Radiative heat fluxes turn out to be several times larger than the convective fluxes. Both homogeneous and separated flow models for the steam-water flow relative to the particles are formulated. In both cases the void fraction rapidly rises to above 0.85, and the particle volume fraction also decreases sharply, indicating rapid bed dispersal. This confirms a simpler calculation by Henry and Fauske of water removal from the heating zone, looked upon as a subcooled critical heat flux calculation. It would therefore appear to be very difficult to have an efficient steam explosion on a scale large enough to threaten the containment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.