Abstract

A model experiment of a submerged gas injection system in a cylindrical vessel under the influence of a rotating magnetic field and its effect on liquid metal mixing is presented. Argon gas is injected through a nozzle into a column of the eutectic alloy GaInSn, which is liquid at room temperature. Without a magnetic field, the bubble plume in the center region of the cylindrical vessel produces a recirculation zone with high fluid velocities near the free surface, while the fluid velocities in the bottom region are rather low. Our measurements revealed the potential of rotating magnetic fields to control both the amplitude of the meridional flow and the bubble distribution and to provide an effective mixing in the whole fluid volume. Various periodic flow patterns were observed in a certain parameter range with respect to variations of the magnetic field strength and the gas flow rate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.