Abstract

This work studied the use of a horizontal high-solid digester for the decentralized anaerobic treatment of horticultural waste (fallen leaves), where the effect of intermittent mixing by a modified double helical ribbon impeller was investigated. Before experimental verification, the flow pattern and theoretical mixing time were first characterized by CFD simulation. Subsequently, three mixing time intervals (i.e., 3 min/3 hr; 18 min/3 hr; 108 min/3 hr) and one control setup (i.e., without mixing) were compared for their performance during start-up and semi-continuous operation. It was found that minimal mixing was necessary for an efficient digester’s start-up but increased mixing intensity for semi-continuous operation. The results were further interpreted by correlating the digester performance and microbial communities. Those microorganisms sensitive to increased mixing intensity were highlighted and analysed.