Abstract

Location of faults on aging cables is of great interest to maintainers of aircraft, cars, power distribution systems, communication systems, etc. One class of methods for locating faults is frequency domain reflectometry (FDR), using sine waves as the forcing function. A new frequency domain method called mixed-signal reflectometry (MSR) is described in this paper and compared to data from phase detection FDR (PDFDR) methods. The MSR is less expensive and smaller than the PDFDR and has very similar performance. A prototype system using the 100-200-MHz bandwidth with 256 40-kHz steps is shown to have a resolution of about 10 cm, very similar to a PDFDR in the same frequency band.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call