Abstract

A commercial mixed-potential gas sensor comprised of a pair of PtAu-YSZ sensing electrodes and a Pt-reference electrode was investigated at isothermal and thermo-cyclic operation under exposure to H2, CO and C3H6 balanced with synthetic air, separately. The sensor showed logarithmic response behavior to the variation of model gas concentration at isothermal operation and strong dependence on temperature. For the first time temperature dependent dynamic response behavior of the sensor was studied by cyclic triangular variation of the operating temperature at a period of 300s in a temperature range between 410°C and 670°C. The electric potential difference (delta V) measurements at thermo-cyclic condition revealed clearly distinct delta V-temperature profiles (ΔVTPs) depending on gas species and remarkable differences between the thermo-cyclic data and the corresponding delta V-values measured at isothermal conditions. Moreover, it was found out that the stability and reversibility of ΔVTPs depends on sensor operating temperature and is a specific characteristic of the individual gas component as well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.