Abstract

The main goal of this work was to quantify the detection of colistin at low levels in urine samples through the practical application of mixed surfactant micellar electrokinetic chromatography–laser-induced fluorescence (MEKC-LIF) analysis method using its advantage of sensitivity and to examine direct injection of biological samples. Colistin (po- lymyxin E) has neither strong UV chromophore nor fluorophore. So, its assay for metabolism, pharmacokinetics studies for bioavailability and bioequivalence are difficult because of poor detectability. Therefore an enhanced UV or fluores-cence detection by chemical derivatization is required. MEKC-LIF method was proposed for colistin with a 488/520 nm argon-ion laser using a pre-CE derivatization with fluorescein isothiocyanate (FITC). Borate buffer was used as background buffer (BGB). The different parameters affecting the proposed derivatization reaction including concentration of the derivatizing reagent, reaction time and temperature were studied and optimized. The derivative was stable for up to 3 days. Different micelles (TX-100 and SDS) were examined as BGB additives separately but negative-charged mixed micelles (SDS/TX-100) were shown to be the best additive to BGB for the analysis of colistin particularly in human urine as they enhance both selectivity and sensitivity of the proposed method. BGB was used with pH 9.5, 10 kV, 8 s inj time, capillary length 75 cm × 75 μm ID (66 cm effective length), detection was LIF Ex 488 nm; Em 520 nm. The method was applied to colistin analysis in human urine and the recovery was > 98% (n = 5). LOD and LOQ in urine after pre-column derivatization using FITC were 100 and 250 ng/ml, respectively. Urine samples were analysed by direct injection without sample pre-treatment. The mechanism of enhancement of fluorescence of the derivative by surfactant was proposed.

Highlights

  • Colistin is a cationic polypeptide and is one of the polymyxin antibiotics known as polymyxin E, produced by Bacillus colistinus

  • The main goal of this work was to quantify the detection of colistin at low levels in urine samples through the practical application of mixed surfactant micellar electrokinetic chromatography-laser-induced fluorescence (MEKC-laser induced fluorescence (LIF)) analysis method using its advantage of sensitivity and to examine direct injection of biological samples

  • A MEKC-LIF using a pre-CE derivatization with fluorescein isothiocyanate (FITC) has been developed for colistin analysis

Read more

Summary

Introduction

Colistin is a cationic polypeptide and is one of the polymyxin antibiotics known as polymyxin E, produced by Bacillus colistinus. It has a significant in vitro activity against some multiresistant Gram-negative pathogens, including Pseudomonas aeruginosa (P. aeruginosa). The two commercially available forms of colistin are colistin sulphate, used topically, and sodium colistin methanesulphonate, used parenterally. Both forms may be given via inhalation. The predominant use over the last 20 years has been for inhalational treatment of P. aeruginosa infection in Cystic Fibrosis (CF) patients [2]

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call